d06703.fm
03 July 2019 76-10-00
Initial Issue Page 12 of 18
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
SI-912 i-024
SI-915 i-006
SERVICE INSTRUCTION
Fig. 12
Attach Amphenol® female connector to Stator B
The following instructions depict the use of DMC® adjustable crimp tools. These tools or equiva-
lent are required to correctly attach connecting pins.
Fig. 13
m
WARNUNG
m
WARNING
Failure to use correct crimping tool(s) may lead to engine damage, person-
al injury or death.
Step Procedure
1
Carefully strip back approximately 10 mm (0.390 in.) of insulation from each of the
three yellow wires (7).
NOTE: Use a quality wire-stripping tool set to 12 AWG (0.0 mm
2
) to avoid dam-
aging wire strands.
2 Set the crimp tool’s wire size to 12 AWG (0.0 mm
2
) (8).
3
Stripped wires must seat fully into crimp pin and have approximately 1 mm (0.039 in.)
gap to insulation (9).
5 Cut off pins
6 Rubber seal
7 10 mm (0.390 in.)
8 12 AWG
9 1 mm (0.039 in.)