SERVICE INSTRUCTION
03 July 2019 76-10-00
Initial Issue Page 13 of 18
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
Fig. 14
Fig. 15
Step Procedure
4
Place the connector pin into crimp tool with crimp-barrel facing outwards. Adjust po-
sitioner until crimp-barrel is flush with the tool (10).
5
Place stripped wire fully into crimp-barrel and hold in place while crimp tool is com-
pressed by hand until fully closed.
NOTE: Crimp tool incorporates a ratcheting mechansim that requires the crimp
tool to be fully closed before releasing.
Step Procedure
6
Remove the wire and crimped connector pin from crimp tool and inspect for correct
crimping.
NOTE: Wire strands must be visible in withness hole (11) and crimps must be
between the witness hole and the end of the crimp-barrel (12).
10 Flush
11 Witness hole
12 Crimps