d06703.fm
03 July 2019 76-10-00
Initial Issue Page 14 of 18
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
SI-912 i-024
SI-915 i-006
SERVICE INSTRUCTION
Assembly of the connector housing Amphenol® part no. 864590
Place numbered wires in the following alphabetical positions:
Fig. 16
Step Procedure
1 Place rear connector screw cap over wires (13).
2
Push connector pins and wires through round rubber seal (14).
NOTE: New connector positions are marked A through D (15), whereas the gray
housing was marked 1 through 4.
Wire Connector position
1A
2B
3C
Step Procedure
3 Place plastic sleeve over wires with key slot (16) towards connector.
Step Procedure
4
Push each wire into connector until its pin snaps securely in place.
NOTE: Correctly secured pins will travel further into connector (18) and lock in
place. Removal requires using extractor tool.
13 Screw cap
14 Rubber seal
15 Position letters
16 Key slot