d06703.fm
SI-912 i-024
SI-915 i-006
SERVICE INSTRUCTION
03 July 2019 76-10-00
Initial Issue Page 5 of 18
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
3) Accomplishment/Instructions
-ROTAX
®
reserves the right to make any amendments to existing documents, which might
become necessary due to this standardization, at the time of next revision or issue.
NOTE: Before maintenance, review the entire documentation to make sure you have a com-
plete understanding of the procedure and requirements.
Accomplish-
ment
All measures must be implemented and confirmed by at least one of the following persons or
organizations:
-ROTAX
®
- Authorized Distributors or their independent Service Centers
- Persons with approved qualifications for the corresponding engine types. Only authorized per-
sons (iRMT, Level Heavy Maintenance) are entitled to carry out this work
NOTE: All work has to be performed in accordance with the relevant Maintenance Manual.
NOTE: Indicates supplementary information which may be needed to fully complete or under-
stand an instruction.
3.1) Installation - related information
3.2) Maintenance (Line) - related information
3.3) Maintenance (Heavy) - related
For the modification of old style connector the following assembly steps do apply:
Pay attention to the specifications of the latest version of the Installation Manual (IM)
for the respective engine type.
See relevant Maintenance Manual (Line) for the respective engine type and its period-
ical maintenance information.
Points of inspection
Interval
Operating hours
Chapter
reference
100 h 200 h
Visual inspection of the wiring harness,
connectors and brackets for secure fit,
damage and signs of wear.
x 12-20-00 section 15.1
Pay attention to the specifications of the latest version of the Maintenance Manual
Heavy (MMH) Chapter 76-10-00 section Fuse box installation for the respective engine
type.

Other manuals for Rotax 912 i series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 912 i series and is the answer not in the manual?

Rotax 912 i series Specifications

General IconGeneral
Number of Cylinders4
Max Power100 hp (73.5 kW)
Max Power Output RPM5800 rpm
Ignition SystemDual electronic ignition
Oil SystemDry sump, forced lubrication with separate oil tank
Reduction Gear Ratio2.43:1
TBO2000 hours
Engine Type4-stroke, horizontally opposed
Displacement1352 cm³
Bore x Stroke84 mm x 61 mm
Max Torque128 Nm
Fuel TypeAvgas 100LL or unleaded automotive gasoline
Fuel SystemElectronic fuel injection
Cooling SystemLiquid/air-cooled