6 x Operation
74
FA ROTEX HeatPumpSolarUnit - Part 2 - 05/2009
27 - Key Weather dependent target value regulation
This key activates or deactivates the function weather-dependent target value regulation. This function is only available in room
heating operation.
If the access authorisation in parameter [0-00] is set to Level 2 or 3, the key "Weather-dependent target value regulation" does
not work.
28- Key Parameter mode, test run
This key is used to set parameters and to start a test run after installation or maintenance work.
29- Key Programming
This multifunction key is used to program the switching times.
30 - Key Program clock
The main function of this multifunction key is to activate/deactivate the program clock. The key is also used to program the
control system. If the access authorisation in parameter [0-00] is set to Level 3, the key Program clock does not work.
31- Key Time setting and
These keys have several functions such as:
Decreasing or increasing adjustment when setting the clock.
Changing between display of the water outlet temperature on the Indoor module (RKHB), the ambient air temperature (outside
temperature) and the hot water temperature in the HybridCube.
Decreasing or increasing adjustment for programming switching times in the program clock.
32 - Keys Temperature setting and
These keys have several functions such as:
Setting the current temperature target value in normal operation or in switching time programming of the program clock.
Setting the weather-dependent target value.
Setting the week day while setting the clock.
33 - Keys Setting hot water temperature and
These keys are used to set the temperature target value for the water heating.
34 - Key Low-noise operation
In this operating mode the output of the system is reduced so that the operating noise of the Outdoor module (RRHQ) is reduced.
35 - Pressure gauge water pressure
The indicator on the pressure gauge must be in the specified range of 1 to 2 bar. If it falls below the specified pressure, the water
pressure must be increased by topping up the system.
1)
The function room cooling is available only for systems of type "HPSU..X".