6 x Operation
96
FA ROTEX HeatPumpSolarUnit - Part 2 - 05/2009
6.5 Accessories
6.5.1 Room thermostat
The room thermostat is used to acquire the temperature values in a room and depending on the user setting, to operate the control
system in the Indoor Module (RKHB). The room thermostat can also be used to switch the operating modes room cooling
1)
and
room heating and also to define individual switching times.
Operating the room thermostat is described in detail in its own operating instructions.
1)
The function room cooling is available only for systems of type "HPSU..X".
6.5.2 Wireless Room Thermostat
The wireless room thermostat is used to acquire the temperature values in a room and depending on the user setting, to operate
the control system in the Indoor Module (RKHB). The wireless room thermostat can also be used to switch the operating modes
room cooling
1)
and room heating and to define individual switching times.
Operating the wireless room thermostat is described in detail in its own operating instructions.
1)
The function room cooling is available only for systems of type "HPSU..X".
6.5.3 ROTEX Solaris System
By connecting the ROTEX Solaris system to the ROTEX HeatPumpSolarUnit, you can stop the water being heated by the heat
pump or by the Booster Heater (EHS). This then allows 100% solar use during water heating.
Operating the ROTEX Solaris system is described in detail in its own operating instructions.
9 Target value temperature ranges for room heating and room cooling
00 Upper limit of target heating value 55 40 37 - 55 1 °C
01 Lower limit of target heating value 15 16 15 - 37 1 °C
02 Upper limit of cooling target value
1)
20 20 18 - 22 1 °C
03 Lower limit of cooling target value
1)
5 10 4 - 18 1 °C
C Priority Solar Support
00 Solar priority 0 0 0 - 1 1 —
Tab. 6-2 Overview parameter settings
1)
The function room cooling is available only for systems of type "HPSU..X".
2)
The ECO values have been ascertained for operation with a ROTEX Monopex underfloor heating
system and are used to operate the system as efficiently as possible.
The ECO setting reduces the performance to such a degree under certain circumstances that it
is no longer possible to reach possible target temperatures.
Code 1
Code 2
Parameter name
Default factory settings
Retrospective
changes
Value ECO
2)
Range Increment Unit Date Value