J Line Pump
Horizontal Double Suction Centrifugal Pump API 610 Process Pump
15 V1.032818
4. Thoroughly dry the pump with hot air.
5. Any painted surface damaged in shipment should be repainted or sprayed with oil.
6. Keep the pump moisture-free by the following two means:
a. Spray the pump case with acid-free, moisture-free, protective oil or kerosene.
b. Place desiccant or humidor bags inside the suction and discharge areas of the pump.
Attach red tags with a “Remove Moisture Absorbent Material Bags Prior to
Installing” to warn about the presence of this desiccant material.
7. Cover all the openings with plywood or metal covers. Recheck the condition of these covers
every month and replace as necessary.
8. If the pump’s external parts have protective coatings, periodically inspect and renew the
coating as required.
9. Rotate the shaft 1 ¼ revolutions every week. Lubricate shaft bearings prior to rotation.
The client must keep a record of the weekly rotation of the shaft. Failure to
document and present these records as evidence will void the warranty.
10. Check the packaging for damage every month.
11. Ensure pump flange covers remain in place.
12. Return the unit to the shipping crate.
13. When the pump is to be installed, remove all the protective coatings and desiccant or drain
all oils.
One month before installation, a Ruhrpumpen representative should be employed to conduct a final
inspection.
To properly store the motor (driver) for periods longer than one month, follow these steps:
1. Store the motor in a clean, dry area, or cover it with a loose tarp (the tarp must be loose in
order to prevent condensation).
2. Exercise precautions to avoid transit or nesting of rodents, snakes, birds, and insects.

Table of Contents