J Line Pump
Horizontal Double Suction Centrifugal Pump API 610 Process Pump
41 V1.032818
Figure 6.1d. Oil tank reservoir.
4. Untighten the socket screws of the oil tank cap.
5. Remove the oil tank cap along the oil tank reservoir.
6. Unscrew and remove the oil tank reservoir from the oil tank cap.
7. Pour oil into the oil tank as necessary until the oil level reaches the label marked on the oil
tank.
8. Place the oil tank cap on the oil tank and tighten the socket screws.
9. Fill the oil tank reservoir up to ¾ of its capacity.
10. Place the oil tank reservoir on the oil tank cap and fasten.
11. The oil tank reservoir of the constant level oiler will have an initial level of approximately two
thirds when it reaches a stable state.
If it is suspected that bearings have been exposed to dirt or moisture, thoroughly
clean the bearings and frame with a solvent and air-dry the parts before adding
lubricant. Disassembly, inspection, cleaning, and reassembly procedures are
provided in SECTION EIGHT - MAINTENANCE.
6.2 PURE OIL MIST DRY SUMP
When pure oil lubrication is supplied, the oil mist is the only lubricant provided.
The oil mist generator must be running before starting the unit.