Loading...
ERROR CODE
E
RROR
DESCRIPTION
CONTROL
DISPLAY WASH RINSE DRY END START/PAUSE
F6
NTC faulty
NTC can be out of order.
Faulty NTC cable connection can be
faulty. NTCshort or open circuit.
Electronic card can be out of order.
FE
Electronic card
parameter faulty
By the Immediate and continuous voltage
decreases software variants can not be
kept in the memory of electronic card
SE
Electronic card water
hardness faulty
Water Hardness is not be adjusted or
Water Hardness adjustment can not be
kept in the elctronic card memory.
Water Hardness shoul be adjusted by
controlling the supply water.
F4
Faulty Flowmeter
Cable connection of flowmeter can be
faulty.
Electronic card can be out of order.
FA
Faulty turbidity
sensor
Kirlilik sensörü kablo bağlantısı hatalı
Turbidity sensor can be out of order.
There can be some soil around the
turbidity sensor.
Electronic card can be out of order.
Door is open
Door lock mechanism can be out order.
There can be o problem with the cable
connection of door lock.
Electronic card can be out of order.