ERROR CODE ERROR DESCRIPTION CONTROL
DISPLAY WASH RINSE DRY END START/PAUSE
F8
Heater Error: Inadequate
heat
NTC can be out of order.
Faulty NTC cable connection
can be faulty. NTCshort or
open circuit.
Thermal protection can be out
of order.
Heater can be out of order or
cable connection can be out
order.
Alarm is active against water
overflow
Floater switch can be out of
order or have a problem with
the cable connection.
Electronic card can be out of
order.
F1
Alarm is active against water
leakage
There can be a water leakage
from the tub.
Floater switch can be out of
order or have a problem with
the cable connection.
Electronic card can be out of
order.
F7
Exceed heating problem
(water inside the machine is
too high)
water inside the machine is
>77°C, NTC can be out of
order.
Electronic card can be out of
order.
F9
Diverter position problem
Diverter electric contacts can
have open circuit
Cable connection of tghe
diverter can be faulty
Electronic card can be out of
order.