FLOATER
From the component :
P
osition 1: You can check the floater by controlling the specified value intervals.
CONNECTORS SHOULD BE MEASURED
Position 2: I
f failure code is occured related with the floater within control the above
values; you can figure out whether leakage occurs or not.
CN2.1 – CN 2.5
0 Ω
CN2.1–CN2.4
∞ Ω
MİCROSWITCH IS
INACTIVE (NO WATER)
MİCROSWITCH IS
ACTIVE (WATER )
ELEKTRONICAL CARD
CONNECTOR
CONNECTOR
ELECTRONİCAL CARD
BLACK
WHİTE
CONNECTORS SHOULD BE MEASURED
RED
WHİTE
CONNECTORS SHOULD BE MEASURED
62