English
8
36
DISPLAY Description
2.3.1.
By setting “Y”, the management of the parallel reader is enabled.
By setting “N”, a parallel reader which may be connected to the vending machine is always disabled.
Enable
no
2.3.2. Enables setting of the active level of the banknote reader inhibition signal.
Inhibition Level
255
2.3.3-4
Enables setting of the value of banknotes transferred to the vending machine from the parallel
reader.
Banknote Value
…
2.4. Enables access to particular functions of the MDB protocol.
MDB settings
…
2.4.1.
It allows disabling or enabling the possibility of performing any Saeco Card recharge operation
By setting RECHARGE = NO the vending machine will only deduct the cost from MDB cards.
Recharge Enabled
no
2.4.2.
Enables setting of the maximum credit level, beyond which all recharge operations (if enabled) are
ineffective.
By setting MAX RECHARGE = 20.00, the credit on the vending machine will be transferred to the
card if the sum does not exceed 20.00.
Max Card Recharge
10.00
2.4.3.
It enables to set the maximum credit level, beyond which the card is rejected by the system.
By setting MAX CARD VALUE = 25.00, the vending machine will reject all cards with a credit
which exceeds this amount.
If this card is detected, the display will not show the credit but a “ ——” message will be displayed
and no sale will be carried out.
Max Card Value
10.00
2.4.4-16
Enables selecting which coins can be accepted by the coin return.
If set on "Y", the specified coin will be accepted.
On the contrary, if set on "N", the specified coin will be rejected by the coin return.
The coins with a value lower than the scale factor of the vending machine are always disabled and marked with "N".
Coins Enabling
…
2.4.5.
It enables / disables the use of Alternative Payout for the level 3 MDB change-giving coiner.
By setting "Yes" the change-giver is called on to dispense change.
Change is limited to 255 times the scaling factor (typically € 12.75 for the Euro area - with scaling factor of 5).
By setting “No” change is given by exploiting the machine’s algorithm.
Max. change is 60000 units (typically € 600 for the Euro area).
Alt. payout
no
2.4.6.
Enables setting of the maximum amount of change which can be dispensed by the change-giving
coiner.
Default = 10.00.
Max change
0.00
2.4.7.
With MDB coin return, the "no change available" status can be selected through the "CHANGE TABLE".
Note
Even if the no change available message is displayed, the vending machine continues to give change as long as
coins are present in the channels.
The minimum level (the same for all channels) can be set on a special menu item.
Exact change policy
0
2.4.8.
Enables setting of the minimum number of coins in the channels.
Default = 4.
Min Tube Level
0
2.4.9.
Allows the coin return tubes to be filled by hand.
Press Esc to exit the channel loading mode.
Manual Tube Filling
…
2.4.10. Allows the change-giving coiner channels to be emptied by pressing the beverage selection keys.
Manual Tube Empty
…