Other codes Code Data Comments
Emergency signal in speaker *71* - # The speaker siren will sound at emergency call.
1 = On
0 = Off (Default)
Ring tone timeout *72* - - # Number of ring signals before dialling the next
number. (8 by default)
Additional input function *73* - # Selects input function:
0 = None (Default)
1 = Filter, blocks the alarm input when active.
2 = LMS (Lift Monitoring System), sends a lift monito-
ring alarm at input activation.
3 = Clear/Maintenance
Additional input type *74* - # 0 = Normally-open contact, NO (Default)
1 = Normally-closed contact, NC
Hot Line *75* - # Phone connects directly to a xed receipient without
dialling a phone number
0 = Standard phone line (Default)
1 = Hotline
Indicator mode *78* - # 0 = Standard, 1 = Strictly EN81-28
2 = Strictly single EN81-28
Voice communication
time-out
*79* - # 1 - 20 minutes xsxs. Standard = 8 min
Reset active alarm
automatically
*80* # 0 = OFF,
1 = ON (Default)
Auto answer *81* - - # No of signals before SafeLine answers incoming call.
Can be set from 00-16 (Default = 02, 00=Unit will not
answer).
Unit number *82* - # Program Unit number 1-9 (Default = 0)
Detect dial tone *83* - # 0 = Off
1 = On (Default)
Set to off if SafeLine has problem to detect the dial
tone.
Receipt to alarm receiver
with P100 protocol
*84* - # Select which message(s) to send to the alarm receiver
at an alarm call.
0 = None (Default)
1 = Start of alarm
2 = Start+end of alarm
Break on new alarm *86* - # Disconnects a call longer than 60 seconds at new
activation of the alarm button and calls the next
emergency call number.
0 = OFF
1 = ON (Default)
Alarm button delay time *87* - - # Delay time from pressing the alarm button until
activating the alarm.
00-25 seconds. (Default = 05)