18
SafeLine MX2 v.5.2.1 EN
Other codes Code Data Comments
Alarm button type *89* - # 0 = Normally-open contact, NO (Default)
1 = Normally-closed contact, NC
Change password *91* - - - - # Change password (default=0000)
Simulate an alarm event *94* - # Triggers an alarm event after programming is terminated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/Loudspeaker failure
5 = Receipt on voice call
6 = Maintenance
7 = Main unit power failure
8 = Stuck button alarm
Reset to default settings *99* - # 1 = Factory default
2 = Default P100(The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*1#
3 = Default CPC(The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*1#
4 = Default VOICE(The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1#, *84*1#, *88*1#
Compatability mode *77* - # 0 = Automatic voice switching
The call is validated when there is a voice response. The
call is terminated by pressing ”#”.
1=KoneECII(lifttelephone)
When there is a voice response, some ascending tones
will be heard. The call is validated by pressing ”4”. The
call is terminated by pressing ”0”. The call is terminated
without reciept notication by pressing ”2”(the unit will
call the next number).
2 = Manual voice switching
When there is a voice response, some ascending tones
will be heard. The call is validated by pressing ”4”. Unit is
still in automatic mode.
To enter manual mode and talk press ”*”.
To listen press ”7”.
Go back to automatic mode press ”4”.
The call is terminated by pressing ”#”.
It is possible to enter manual voice switching mode
although the unit is programmed as automatic by pres-
sing ”*”. No ascending tones will be heard. For repeating
the voice message, press “1” in all modes.