Confi guration
CONFIGURATION DATA CODE DATA COMMENTS
Enter confi guration mode 00
Enter password * - - - - # Default = 0000
Exit confi guration mode *00*#
ALARM CODES CODE DATA COMMENTS
P100 ID code *01* - - - - - - - - # P100 is always 8 digits.
CPC ID code *02* - - - - - - # CPC 6-8 digits.
Q23 ID code *03* - - - - - - - - - - - - # Q23 is always 12 digits.
TELEPHONE NUMBERS CODE DATA COMMENTS
1st Phone number *11* - - - - - - - - - # Phone number to alarm receiver 0-16 digits.
If calling through a switch board, delay time can be set by
adding asterisks between leading number of the switchboard and
telephone number for the alarm receiver.
Each asterisk is equal to one second delay.
Example: *11*(0)**1234567#
2nd Phone number *12* - - - - - - - - - #
3rd Phone number *13* - - - - - - - - - #
4th Phone number *14* - - - - - - - - - #
CALL TYPE CODE DATA COMMENTS
Call type 1st number *21* - # Change the call type for the telephone numbers stored.
0 = P100
1 = VOICE (Default)
2 = Q23
3 = CPC
Change this only if your alarm operator is using any of the
mentioned protocols.
Call type 2nd number *22* - #
Call type 3rd number *23* - #
Call type 4th number *24* - #
Call type LMS number *30* - # LMS (Lift Monitoring System) call type:
0 = P100
3 = CPC (Only battery alarm)
4 = Caller ID (Battery powered only)
TEST ALARM/BATTERY ALARM CODE DATA COMMENTS
LMS phone number *16* - - - - - - - - - # LMS (Lift Monitoring System) phone number to alarm receiver/
SLCC.
Test alarm *17* - - - - - - - - - # Phone number to test alarm receiver/SLCC.
Days between tests *27* - - # Number of days between test alarms, 00-99 days. Always two
digits. Max 3 days according to EN 81-28.
00 = No test alarms
Test alarm protocol *31* - # Protocol test alarm:
0 = P100
3 = CPC
4 = Phone number used as ID.
ALARM CHARACTER CODE D ATA COMMENTS
Alarm character 1st number *41* - - # Alarm character. only when using CPC as alarm protocol
normally 10 or 27 check with your alarm company !
Alarm character 2nd number *42* - - #
Alarm character 3rd number *43* - - #
Alarm character 4th number *44* - - #
Alarm character LMS *45* - - # LMS (Lift Monitoring System) (Battery alarm) Normally 17.
Alarm character Test alarm *46* - - # Normally 26.