Alarms
An alarm mechanism is implemented on application to detect any unwanted or suspicious behaviour
during the meter lifetime. The bit assignment for alarms register is as follows:
Bitfield
Alarm name
Description
1
Low air temperature
Air temperature below threshold
2
High air temperature
Air temperature above threshold
3
Low water tempera-
ture
Water temperature below threshold
4
High water tempera-
ture
Water temperature above threshold
5
Fraud suspicion
Fraud is suspected when several attempts to access one of
the input interfaces are detected.
6
Small water leakage
Small water leakage is sometimes present in the water sys-
tem and causes unwanted water waste over time
7
Hard water leakage
Hard water leakage is present when one of the water equip-
ments is draining water, if a pipe has serious damage or if a
faucet is left open
8
Air bubbles
Bubbles are present in water which may lead to unreliable
measurements
9
No water
Pipe is not filled with water
10
Hardware error
Meter hardware error
11
No consumption
Meter didn’t measure any flow during a detection window
12
Water backflow
Backflow is an unwanted flow of water in the reverse direc-
tion. The reverse flow happens when the local water system
presents a higher pressure than in its supply network or
when the supply is interrupted or drained down.
13
Low battery
Low battery level
14
Critical battery
Extremely low battery level. The product must be replaced.
15
Metrological CRC er-
ror
Metrological firmware CRC is incorrect
16
Tampering
Meter is tampered, dismantled
17
Water overflow
Overflow is detected when water flow exceeds the maxi-
mum allowed flow
[18 .. 31]
Reserved for future
use
NB: all thresholds in the table above are configurable.