94
4.3.5
4.3.5
4.3.5
4.3.5 Constant
Constant
Constant
Constant Setup
Setup
Setup
Setup
For the integrator which is newly put into service or just replaced the battery module, the
constant should be input according to the initial calibration.
· Power the integrator on
· Input belt speed (establish test duration in calibration menu, the belt must have been
running for over 30 minutes with no load.)
· I nput other constants (zero, span, scale capacity, etc)
4.4
4.4
4.4
4.4 Usual
Usual
Usual
Usual Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
W hen the material is smoothly delivered but the flowrate indication in integrator varies
greatly, there may be various reasons such as: broken load cell, damaged speed sensor, bad
integrator, defective mechanical construction, signal interference, etc. The former three
factors have been mentioned hereinbefore.
The defective mechanical structure on the site mainly contains: inactive trunnion (adjust the
trunnion screw to improve), loose pull bar (fasten the set nut to improve), material blockage
(clear off material to improve). Eliminate any potential problems perceptible. Signal
interference is mainly caused by electromagnetic field . The preventative measures is to route
the signal cable separate from power cable far away, and ensure that the integrator is
grounded well (comply with the grounding specification).