6101
6101
6101
6101 Belt
Belt
Belt
Belt Scale
Scale
Scale
Scale Integrator
Integrator
Integrator
Integrator Operating
Operating
Operating
Operating and
and
and
and Service
Service
Service
Service Manual
Manual
Manual
Manual
2
weights or test chain on the weighbridge. The electronic calibration checks all the
circuitry including the load cell, and is performed by unbalancing the load cell
bridge using a precision resistor. The calibration constant is calculated on the basis
of the load cell and the scale data.
· Test Weight Calibration
Requires the positioning of test weights on the weighbridge
· Chain Calibration
Requires the application of calibrated chains on the belt. This method is the
nearest to actual operating conditions.
· Material Calibration
Is performed by running a known quantity of material on the scale and weighing
that quantity on a static scale of known accuracy.
4. Zero Tracking (AZT)
Under a preset minimum flowrate when enabled, the instrument makes subsequent
automatic zero calibrations with the following sequence:
· performs automatic zero for one test duration.
· continuously repeats above zero calibration as long as feed rate remains below AZT
preset value.
Zero Tracking has Max. Tracking range , which is setup with % in System
data Menu .
5. Current Output Signals
An optional current output/analog input board is available. Each current output may
be programmed via the keyboard to deliver one of the following signals:
· flowrate
· belt loading
· belt speed
1.3.2
1.3.2
1.3.2
1.3.2 Monitoring
Monitoring
Monitoring
Monitoring Function
Function
Function
Function
Saimo 6101 integrator is equipped with an indication system. Indication can be in the
form of:
· status indications
· process alarms
· programming errors
· equipment failures
The integrator includes internal diagnostics that will generate alarms in case of
hardware failures or programming errors. The following process alarms are also
provided:
· Belt slip (two speed sensors recommended)
· Alarms for high and low flowrate, speed and weight
These alarms are visible on the display and can be acknowledged and reset through
keyboard, digital input or serial line. Alarms can be delayed to avoid intervention in
case of short time peaks. Each individual alarm can be programmed to operate as
alarm, shut down or to be ignored.
1.3.3
1.3.3
1.3.3
1.3.3 Printing
Printing
Printing
Printing Function
Function
Function
Function
Periodical and under command prints can be obtained by connecting a serial printer to
an optional communication board.

Questions and Answers: