63
Press to select submenu, use numeric key to input the value desired and then press
ENT to confirm.
3
3
3
3 .
.
.
. 2
2
2
2 .
.
.
. 4
4
4
4
Simulated
Simulated
Simulated
Simulated constant
constant
constant
constant
calculation
calculation
calculation
calculation
Simulated consant must be proper, not over large or over little.
T he Simulated C onst ant must be calculated by a proper method depending on the
selected calibration mode.
1) For electronic calibration mode, the calculation formula is
Equivalent weight =
( )
1
1
2
1
..
2
S
R
R
LCS
kg
K
+
In which: L.C.S —— Load cell capacity kg
K —— Load cell sensitivity mv/V
RS —— Resistor used in electronic calibration (Ohms)
R1 —— Load cell input resistor (Ohms)
Take the following conditions for example:
L.C.S=200kg
K=0.003V/V
RS=100000 Ω
R1=350 Ω
Then Equivalent weight =
1
2100000
1
350
200
20.003
×
+
×
=58.23kg
Equivalent weight on unit length =
1
2
1
cos
dkg
dD ϕ
××
kg/m
In which kg —— Equivalent weight
ϕ
—— Angle between the scale on the conveyor and the horizontal plane
d1 —— Distance from trunnion pivot centerline to load cell centerline (mm)
d2 —— Distance from trunnion pivot centerline to weigh idler centerline (mm)
D —— Measuring section length (m)
Take the following conditions for example:
kg=58.23kg
ϕ
=15o
d1=812.8mm
d2=609.6mm
D=3m
Then Equivalent Weight =
58.23812.81
0.966609.63
××
=26.79kg/m
The Simulated Constant = Equivalent weight on unit length X Test length
= Equivalent weight on unit length X (Belt full length X revolutions)
= 26.79kg/m X (100m X 25 revs = 26790kg = 26.79t
2) For test weights calibration mode, the following method should be used:
a) The Equivalent Load (Kg/m) =
DengthWeighSpanL
KgsTestWeight
Test Weights = Static weight applied on the weigh idlers
Weigh Span Length = Idler spacing X Number of weigh idlers
For example: