32
Pressing PAGE DONE soft key enters the third page of the System Data Menu.
Pressing PAGE DONE soft key enters the fourth page of the System Data Menu.
5.3.3.2
5.3.3.2
5.3.3.2
5.3.3.2 Calibration
Calibration
Calibration
Calibration Data
Data
Data
Data
Press PAGE DOWN soft key, the first page of the Calibration Data Menu is displayed.
2006-3-21 12:00:00 Scale #1
TIME SETUP
Hour: [ 12 ]
Minute: [ 0 ]
Second: [ 0 ]
Press
or
key
then press ENT!
MAIN PAGE PAGE
MENU DOWN UP
2006-3-21 12:00:00 Scale #1
SCALE DATE
Max Speed: [3 m/s ]
Press
or
key
then press ENT!
MAIN PAGE PAGE
MENU DOWN UP
2006-3-21 12:00:00 Scale #1
CALIBRATION
DATA
1
Simulated: [ELECTRIC ]
Resistor: [ 165000Ohms ]
Weights: [ 100kg ]
Chain: [ 100kg/m ]
Press or key, then press ENT!
MAIN PAGE PAGE
MENU DOWN UP