6105
6105
6105
6105 Belt
Belt
Belt
Belt Feeder
Feeder
Feeder
Feeder integrator
integrator
integrator
integrator ---
---
---
--- User
User
User
User ’
’
’
’ s
s
s
s Guide
Guide
Guide
Guide ---
---
---
---
3
1.2
Technical
Technical
Technical
Technical Specifications
Specifications
Specifications
Specifications
(a) Chinese / English menu
(b) Weighing Capability
· The 6105 integrator is capable of connecting up to eight 350 Ω loads and acquiring a speed signal
from the speed sensor, to calculate flow rate and total.
· The 6105 integrator has the function of automatic zero calibration.
(c) Ambient Environment
· Location: Indoor or outdoor, as close as possible to the load cells, free from damp and dust.
· Temperature:
Storage temperature : -40~+70
º
C
Operati ng temperature -10~+50 º C
· Max imum Relative Humidity: 95%
(d) Power Requirements
· 220VAC ± 10% or 110VAC ± 10% 50Hz
· Fuse: 2A
· EMI / RFI filter
(e) Load Cell
· offers 10VDC (+/- 10% ), 5 00mA excited power , up to 8 load cell s
· Sensitivity : 0.5mV/V ~ 3.5mV/V
· Max. input signal 33mV
· L oad cell shield grounding
· E xcitation compensation circuit is employed when the cable distance is over 60 meters but less
than 900 meters .
· Local or remote compensation can be selected by a jumper set.
(f) Mainboard Digital Input
The mainboard provides 6 programmable inputs for receiving dry contact on-off signal
(g) Mainboard Digital Output
The mainboard provides 8 programmable outputs.
(h) Outline Dimensions
Panel mount: Outliner dimensions: 288mm x 144mm x185mm
Front panel dimensions: 284mm x140mm
Field mount: Outline dimensions: 312mm x 380mm x 150mm
Mounting hole dimensions: 240mm x 450mm