Depending on your battery types, the cable connection might be different, as shown below.
4.7. Assembling the PV-side Electrical Connection
About this task
The inverter cannot be used with functionally earthed PV arrays.
A positive connector and a negative connector are provided in the accessory bag.
Prerequisite
The PV array is properly insulated to ground before it is connected to the inverter.
Select cables according to the below specification. For details, refer to the inverter user manual.
Specification
Range
Recommended value
Conductor cross-sectional area of cables (mm²)
4.0 – 6.0
4.0
External diameter (mm)
4.2 – 5.3
5.3
The positive cable is connected to the positive side of the solar panels, and the negative cable is
connected to the negative side of the solar panels.
The DC switch on the inverter is in OFF position. For further safety considerations, use a reliable tool
(such as a lock with a key) to lock the switch, so that others cannot unlock it easily.
BMS/CAN
BAT+ BAT-
Inverter
COM
BAT-
BAT+
Inverter
BAT1-
BAT1+
CAN1