Hybrid Solar Inverter User Manual
9
10
MODEL
H2-5K-T2
H2-6K-T2
H2-8K-T 2
H2-10K-T2
Total Harmonic Distortion of Voltage
<3%
Peak Output Apparent Power [VA]
10000, 60s
12000, 60s
16000, 60s
16500, 60s
Efficiency
Max. Efficiency
98.0%
Euro Efficiency
97.6%
MPPT Efficiency
>99.9%
Max. Battery Charging/ Discharging Efficiency
97.6%
Protection
AC Short
Circuit
Protection
Integrated
Overload Protection
Integrated
Residual Current Monitoring Unit
Integrated
Battery Input Reverse Polarity Protection
Integrated
Anti-islanding protection
Integrated
AC Surge Protection
Type III
DC Surge Protection
Type
III
Interface
PV Connection Type
D4, MC4 (optional)
Battery Connection Type
Quick connector
AC Output
Plug-in connector
Display
LED+APP
Communication port
CAN, RS485, DRM, RS232
Communication
Wi-Fi, Ethernet, 4G (optional)
General
Data
Topology
Non-isolated
Ingress Protection
IP65
Operating Temperature Range
-25°C to +60°C
Ambient Humidity
0
100% No condensing
Altitude
4000m (>3000m power derating)
Noise [dBA]
<30
Cooling method
Natural convection
Dimensions [H*W*D] [mm]
433*549*207
Weight [kg]
25
Standard Warranty [year]
Refer to the warranty policy.
Applicable Standard
CEI 0-21, VDE4105-AR-N, VDE0126-1-1, EN50438, G98, G99, EN50549, AS4777.2
IEC62109-1&-2, IEC62040-1, EN61000-6-1/2/3/4