10
4. RXRT510 receiver
4.1 Receiver’s switches description
The thermostat communicates wirelessly with the RXRT510 receiver. The receiver should be supplied with 230VAC, the maximum load of the receiver is
16A. Avoid installing the device in places directly exposed to water, moisture and air condensation. The RXRT510 receiver can operate in two dierent
modes - AUTO (automatic) and MANUAL (manual). To select a specic mode, use the switches on the front of the receiver.
For the receiver to work with the thermostat, set the switches to the ON / AUTO position.
2.
4.
3.
1.
TOP SWITCH
1. ON - Manual mode - receiver ON
2. OFF - Manual mode - receiver OFF
BOTTOM SWITCH
3.
AUTO - Receiver works in AUTO mode (according to
the thermostat’s command)
4.
MANUAL - Receiver works in manual mode
(according to the ON/OFF switch)
REMEMBER!: