RT500RF INSTRUCTION MANUAL
11
To adjust the RF address code of the Control Centre, remove one or more of
the jumper caps located on the back of the unit (labelled 1,2,3,4 and 5, and
shown in the picture below) so that the jumper settings match the settings
made on the receiver:
For example, if the DIP switches on the Receiver were set as follows:
1-ON
2 - OFF
3 - OFF
4 - OFF
5-ON
Then you would need to remove jumper caps 2, 3 and 4 on the Control
Centre to make sure that they are both set with the same RF address code.
Please make sure that you keep any of the jumper caps you remove in a safe
place, in case you later need to change the RF address setting again.
You must press RESET on the Control Centre after making any changes to
the RF address code settings.