RT500RF INSTRUCTION MANUAL
9
CONTROL CENTRE JUMPER SETTINGS
Changes to the jumper settings should only be made by the Engineer
carrying out the installation or other qualified person.
The installer should select the jumper
positions required if changes need to be
made to the factory default settings. These
jumpers are found on the rear of the
Control Centre.
Jumper Function
Program Jumper for 5-2 (factory default setting) or 7
individual days programming.
Span Movable jumper for selecting temperature span
of ± 0.5°C (factory default setting) or ± 1.0°C
1,2,3,4,5 Removable jumpers for altering the RF address
code when used in conjunction with the
corresponding DIP switch on the Receiver.
NOTE:
The Reset button must be pressed after changing jumper positions.
Salus RT500RF Manual:89 9/7/10 10:10 Page 9