DOCUMENTATION
ELECTRONIC MIXING SYSTEM
CYCLOMIX
MICRO / MICRO+ / MICRO+ PH / MICRO+ PH+
Manual : 582.079.110-UK - 1902
Date: 07/02/19
Supersede : 23/05/16
Modif.:
TRANSLATION FROM THE ORIGINAL MANUAL
IMPORTANT : Before assembly and start-up, please read and clearly understand all the documents relating to
this equipment (professional use only).
THE PICTURES AND DRAWINGS ARE NON CONTRACTUAL. WE RESERVE THE RIGHT TO MAKE CHANGES WITHOUT PRIOR NOTICE..
SAMES KREMLIN SAS
l
13, chemin de Malacher
38 240 - MEYLAN - France
: 33 (0)4 76 41 60 60
www.sames-kremlin.com

Questions and Answers

  • A
    Amber KirbyAug 2, 2025
    What to do if the mixing ratio is incorrect with my SAMES KREMLIN Mixer?
    • C
      cmckeeAug 2, 2025
      If the mixing ratio is incorrect, check the pressure differential. The catalyst (CATA) pressure must be higher than the base (BASE) pressure by 15%.
  • J
    Joseph KelleyAug 7, 2025
    What to do if there is no signal from the flow-switch in my SAMES KREMLIN Cyclomix Micro Mixer?
    • G
      gambleloriAug 7, 2025
      If there is no signal from the flow-switch while there are impulses on the base flowmeter or the catalyst flowmeter, check the operation of the flow-switch and replace it if necessary. Also, control the operation of the electronic card and increase the value of P12.
  • A
    Amanda MccarthyAug 12, 2025
    What to do if time between air opening and fluid opening is too long in SAMES KREMLIN Mixer?
    • D
      Dr. Todd Garcia DVMAug 12, 2025
      If the time between air opening and fluid opening is longer than 6 seconds, and the flow switch is blocked or there is an air leak, trigger the gun quicker or change the flow switch.
  • B
    Beverly WallaceAug 17, 2025
    What to do if the VP6 valve is leaking in my SAMES KREMLIN Cyclomix Micro?
    • D
      dmurphyAug 17, 2025
      If the VP6 valve is leaking, remove the VP6 valve and check its correct operation. If necessary, change the valve.
  • C
    Carrie AlexanderAug 22, 2025
    How to fix a blocked BASE flowmeter in SAMES KREMLIN Mixer?
    • B
      Bonnie Robbins DVMAug 22, 2025
      To fix a blocked BASE flowmeter, check the fluid circuit, including the pump and valve. Clean or change them as necessary. Also, check or install a filter upstream of the flowmeter.
  • M
    Melissa AguirreAug 28, 2025
    How to fix a blocked CATA flowmeter in SAMES KREMLIN Mixer?
    • M
      Michael McdonaldAug 28, 2025
      To fix a blocked CATA flowmeter, check the fluid circuit, including the pump and valve. Clean or change them as necessary. Also, check or install a filter upstream of the flowmeter.

Summary

General Safety Instructions

Installation Requirements

Guidelines for safe and proper installation of the equipment.

Equipment Requirements

Specifies necessary equipment and precautions for safe operation.

Operating Principle

Installation Procedures

Implantation

Guidelines for correct and incorrect physical placement of components.

Connection of the Control Unit and of the Fluid Part

Details on connecting the control unit, fluid module, and power.

System Operation

Initial System Setup

Initial Operation and Setup

Application Programming and Configuration

Production Mode (F1)

Flushing Mode (F2)

Maintenance and Troubleshooting

Troubleshooting

Identifies common problems, causes, and solutions for the system.

Diagnostics

Systematic checks for electrical and fluid system faults.

Disassembly and Reassembly

SAMES KREMLIN Cyclomix Micro Specifications

General IconGeneral
BrandSAMES KREMLIN
ModelCyclomix Micro
CategoryMixer
LanguageEnglish