• From these displayed elements .txt (difficult to read up), make a simple "copy/paste" in an Excel
file and data will appear as per that screen :
14. INDICATIONS GIVEN BY THE LEDS
Description Function Action
Red LED Fault The CYCLOMIX
TM
MICRO stops.
Orange LED Working Function other than production (flushing, pot-
life alarm …)
Green LED Production
Green + orange LED Waiting
LED switched off Programming
15. MAINTENANCE
Guards (air motor cover, coupling shields, connectors,…) have been designed for
safe use of the equipment.
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards.
SAMES KREMLIN Page 31 Manual : 573.191.112