Parameters Description
Factory
adjustment
For the 3
programs
Your
adjustment
Program 1
Your
adjustment
Program 2
Your
adjustment
Program 3
Parameter of the fluid dry extract to
count the VOC
Minimum value : 0%
Maximum value : 100%
55 %
Parameter of volume by tooth of
base flowmeter. You must change
that parameter when changing the
flowmeter.
Minimum value : 0.01 c.c
Maximum value : 2.00 c.c
0.24 c.c
(Value of
origin)
Parameter of volume by tooth of
catalyst flowmeter. You must
change that parameter when
changing the flowmeter.
Minimum value : 0.01 c.c
Maximum value : 2.00 c.c
0.24 c.c
(Value of
origin)
Parameter of time between the air
opening and the fluid opening
before fault
Minimum value : 1 s
Maximum value : 10 s
6 s
(Value of
origin)
Parameter of the proportioning test
: to activate this parameter
-
Handling of the error 6 in the
operating of the
CYCLOMIX
TM
MICRO
during the production
sequence (parameter available for
CYCLOMIX
TM
MICRO with serial
number > 14 V 1152).
Minimum value : 0 pulse
Maximum value : 5000 pulses
100 pulses
(Value of
origin)