Index revision : C - July 2021 22 7132
7. Maintenance
WARNING : Switch off the power supply to the control module before connecting the spray gun.
Before disconnecting the spray gun, switch off, disconnect the power supply to the Inocontroller
or Inobox (otherwise, a malfunction may occur).
WARNING : Never throw or intentionally drop the gun. Dropping the gun could damage the
high-voltage unit. After a fall, it is recommended to check the operation of the gun out of the
area before re-use and its condition.
7.1. Summary table of maintenance operations
The dirt and wear of the Inogun M spray gun caused by the passage of powder depends on
the nature of the powder and the operating conditions.
Therefore, the frequency of the interview indicated in the procedures below is only indicative.
As the SAMES KREMLIN equipment is used, the user must create his own maintenance pro-
gram.
Procedure Detail
Preven-
tive
Correc-
tive
Dura-
tion
Frequency
A
A1 Cleaning of spray gun exterior
X 2 mn 8 Hours
A2
Cleaning of electrode support
and deflector
X 2 mn 8 Hours
B
Spray gun maintenance
B1
Replacement of fixing hook X 2 mn
-
B2 Replacement of trigger
X5 mn
-
C
Barrel maintenance
C1
Assembly / Disassembly barrel /
handle
X
5 mm
-
C2 Replacement of HVU
X
5 mm
-
C3
Replacement of air connector
o-rings
X
5 mm
-
D
Handle maintenance
D1
Powder duct
X2 mn -
D2
Replacement of low voltage
cable
X5 mn
-
D3 Replacement of control box
X5 mn -