Appendix A Outdoor GPS Antenna Installation
Verizon 4G LTE Network Extender 2 User Guide v1.1 68
Copyright © 2017, All Rights Reserved.
Grounding the Optional GPS Arrestor
The way to connect the ground cable with the GPS arrestor is as follows.
Table 23. Grounding the GPS Arrestor (MGB GPS Arrestor)
Installation section MGB ground terminal of arrestor
Cable AWG8, F-GV 6 mm2 × 1C/1 EA
Heat shrink tube
(spec/color/length)
Ф 0.4 in. (10 mm)/Green/1.97 in. (50 mm)
Pressure terminal MGB
Checking the MGB specifications per site and preparing
fasteners
Arrestor 6 mm2, ring type, hole dia.: 0.21 in. (5.3 mm)
Fastener MGB
Checking the MGB specifications per site and preparing
fasteners
Arrestor M5 hex. bolt/1 EA
M5 spring washer/1 EA
M5 plane washer/1 EA
(attached at the GPS arrestor)
Recommended torque
value (kgf.cm)
M5 hex. bolt 1.45~2.17 ft.lb. (20 ~ 30 kgf.cm)
Working tools
Cable cutter, wire stripper, compressor, heating gun, torque driver (+), torque wrench,
and nipper
Pressure Terminal for Grounding
As for the pressure terminal or the cable, the UL listed products or equivalent
should be used.
For example:
Manufacturer: JEONO Electric
GPS Arrestor: 6 mm2 Pressure Terminal (JOR 6-5)