Troubleshooting _ 21
Check Type For USA Causes Remarks
Foaming
Detected
SUD
- This occurs when too much foaming is detected. It is also
displayed while foaming is removed. When the removal is
nished,thenormalcycleproceeds.
“Sud” or “SUdS” is displayed when too much foaming is
detected and “End” is displayed when the removal of the
foamingisnished.
(Thisisoneofthenormaloperations.ItisanCheckfor
preventing non-sensing faults.)
Mems PBA
Check Detected
8C1
- CheckdetectedintheMemsPBAordataCheckdetected.
Checkthewireconnections.
Replace if necessary.
1. Checkthewireconnections.
2. Replace the Mems PBA.
3. MainPBAwireconnectionCheckorPBA’ssilvernanopart
malfunction. Replace if necessary.
8C2
8C
Clutch motor PC - Whenpositionoftheclutchcan’tbedetected.
Clutch sensor PC1
- Afterpositionoftheclutchisdetected,ifthesignaloftheclutch
hallgoeswrong,occurserror.
System Check SF - Micro Controller Operation Fail. Replace Assy PCB.