EasyManuals Logo

Samsung AC100RN4PKG User Manual

Samsung AC100RN4PKG
257 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #195 background imageLoading...
Page #195 background image
Troubleshooting
Samsung Electronics 4-39
4-3-15 Compressor starting error / rotation error (Error Code : E461, E467)
1. Test items
1) Check the power connection. / Check the restart after power reset.
2) Check the compressor and the state of the compressor wire assembling.
3) Check the defective for compressor wire single parts.
2. Check procedure
Yes
Continue
Yes
Power on 30 seconds after power off.
End the service.
No
Check the power connection. /
Check the restart after power reset.
1. Is there any problem in input power?
(Single-phase: 220Vac, 3-phase: 380Vac)
2. Does error occur again after
power reset?
Yes
1. Replace the compressor : If the resistance value
between phases of the compressor is different.


2
. Reassemble wire : If the wire connection of the
compressor is wrong.


3. Replac
e the compressor : When loud abnormal
noise generates (metal cutting or grinding noise),
or severe vibration.
No
Check the compressor
and connection of compressor wires.
1. Are all the resistance values between phases
matched? (U V, U W, V W)
2. Is compressor wiring normal?
(disconnection, wrong connection)
3. Is there any abnormal noise
from compressor rotation?
Replace the compressor.
No

between compressor body and chassis?

Table of Contents

Other manuals for Samsung AC100RN4PKG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Samsung AC100RN4PKG and is the answer not in the manual?

Samsung AC100RN4PKG Specifications

General IconGeneral
BrandSamsung
ModelAC100RN4PKG
CategoryAir Conditioner
LanguageEnglish

Related product manuals