EasyManua.ls Logo

Samsung AM080xXV Series - DC Link Voltage Sensor Error

Samsung AM080xXV Series
273 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
Samsung Electronics 4-79
4-3-49 DC Link voltage sensor error
Outdoor unit display
(INVERTER1 PCB) (INVERTER2 PCB)
(OUTDOOR FAN 1 PCB)
Judgment Method
∙ DC voltage detection : Error judgment where the voltage value is more than 4.8V or less than 0.2V.
Cause of problem
∙ DC Link Connector disconnected
∙ PCB voltage sensing circuit defective
Check the connector
connection
Check the status of DC LINK Connector
Power Off
Replace FAN PCB
E496
E469
Replace No1 INVERTER PCB
E369
Replace No2 INVERTER PCB
1.
Cause of problem
DC power wire (Inv. PCB)
DC power wire (Fan PCB)

Table of Contents

Related product manuals