37
ENGLISH
Refrigerant pipe installation
࡛When installing, make sure there is no leakage. When collecting the refrigerant, stop the
ʀͱΧθʪϑϑͱθѣθϑϩɵʪ˙ͱθʪθʪͱЭ˝ϩ˵ʪʀͱʪʀϩͱΧΧʪ࢏Ã˙ϩ˵ʪθʪ˙θ˝ʪθɇϩΧΧʪϑͱϩΧθͱΧʪθц
connected and the compressor works with the service valve open, the pipe inhales the air and it
makes the pressure inside of the refrigerant cycle abnormally high which may lead to explosion
and injury.
WARNING
Refrigerant pipe work
The length of refrigerant pipe should be as short as possible and the height difference between an indoor
and outdoor unit should be minimized.
Piping work must be done within allowable piping length, height difference, and the allowable length after
branching.
Ɵ˵ʪΧθʪϑϑЇθʪͱ˙ϩ˵ʪŵࣛߦߣߢϑ˵˝˵࢏Ƹϑʪͱцʀʪθϩѣʪʒθʪ˙θ˝ʪθɇϩΧΧʪɇʒ˙ͱͱиϩ˵ʪϑϩɇɇϩͱʪϩ˵ͱʒ࢏
After installing the pipes, calculate the total length of the pipe to check if additional refrigerant is needed.
When you need to charge the additional refrigerant, make sure to use R-410A refrigerant.
Use clean refrigerant pipe and there shouldn’t be any harmful ion, oxide, dust, iron content or moisture
inside pipe.
Ƹϑʪϩͱͱϑɇʒɇʀʀʪϑϑͱθʪϑϩ˵ɇϩѣϩͱŵࣛߦߣߢͱц
Tool Installation process/purpose Compatibility with conventional tool
Pipe cutter
Refrigerant pipe
installation
Pipe cutting
Compatible
Flaring tool ťΧʪѤɇθ˝
Refrigerant
machine oil
Apply
refrigerant oil
ͱѤɇθʪʒΧɇθϩ
Exclusive ether oil, ester oil, alkali benzene oil or synthetic
oil
Torque wrench
AͱʪʀϩѤɇθʪ
nut with pipe
Compatible
Pipe bender Pipe bending
Nitrogen gas
Air tightness
test
Prevent
oxidation within
the pipe
Welder Pipe welding
Manifold gage
Air tightness
ϩʪϑϩɇʒʒϩͱɇ
refrigerant
charging
Vacuuming,
charging
refrigerant
and checking
operation
Need exclusive one to prevent mixture of R-22 refrigerant
oil use and also the measurement is not available due to
high pressure
Refrigerant
charging hose
Need exclusive one since there is risk of refrigerant leakage
ͱθѤͱиͱ˙ΧЇθϩʪϑ
Vacuum pump Pipe drying
Compatible (Use products which contain the check valve to
ΧθʪЭʪϩϩ˵ʪͱ˙θͱѤͱи˝ɵɇʀиɇθʒϩͱϩ˵ʪͱЇϩʒͱͱθЇϩ࢏࣒
Use the one that can be vacuumed up to -100.7kpa(5Torr).
Scale for
refrigerant
charging
Refrigerant charging Compatible
Gas leak
detector
Gas leak test
Need exclusive one
(Ones used for R-134a is compatible)
Flare nut
đЇϑϩЇϑʪϩ˵ʪѤɇθʪЇϩʪαЇΧΧʪʒиϩ˵ϩ˵ʪΧθͱʒЇʀϩ࢏ŵʪ˙θ˝ʪθɇϩʪɇɇ˝ʪɇцͱʀʀЇθи˵ʪϩ˵ʪ
ʀͱЭʪϩͱɇѤɇθʪЇϩ˙ͱθŵࣛߤߤϑЇϑʪʒ࢏

Related product manuals