4-4-23. Temperature and Humidity Ranges
Samsung Electronics
4-38
Installation
The following table indicates the temperature and humidity ranges, within which the air conditioner can be used.
If the air conditioner is used at... Then...
The automatic protection feature may be triggered and the air
conditioner stopped.
High temperature
A water leakage or some other
malfunction may happen if the heat exchanger freezes.
Low temperature
Water may condense on and drip from the surface of the
indoor unit if it is used for a long periods.
High humidity levels
Mode Outdoor Temperature Indoor Temperature Indoor Humidity
Heating
Cooling
Drying
-5°C to 21°C approx.
-5°C to 43°C approx.
21°C to 43°C approx.
15°C to 27°C approx.
21°C to 32°C approx.
21°C to 32°C approx.
-
80% or less
-
❇ If the heating operation is used at below 0°C(outdoor temperature) then, does not a full capacity.
If the cooling operation is used at over 33°C(indoor temperature) then, does not a full capacity.
Duct-ADH1800E-2-2 6/27/00 10:37 AM Page 4-38