- 32/47 -
Step 6
① When it freezes only EVAP BOTTOM
- Improve DRAIN freezing.
② Check the drain hole blocking with
removing freezing with STEAMER.
(Remove DRAIN freezing and foreign
substance)
③ Bend the HATER to bottom with hand.
- DRAIN HOLE should be closed.
★ HEATER can not contact to PLATE.
Step 7 (Total inspection after defrost repairing)
① Check the heater operation with forced
defrost operation after complete repairing.
Press “Lighting”+ “Fridge” at the same time
and operate forced defrost to press “Fridge”
key 2times after all LED off.
Check the HEATER(Brown-wire) AC voltage
supplying when “beep” sound appears.
② Off with same way when there is no problem.
①Forced operation
(LED Full On)
↓
②Forced defrost
↓
③ OFF
Step 8
① Inspect Main PBA and Connector open when
the AC power is not supplied.
② Replace the Main PBA if there is no problem.
Inspect MAIN PBA CN70 No.5
(BRN)+CN71 No.1(ORG)
- LINER CONNECTOR BROWN
2WIRE
LED ALL OFF