EasyManua.ls Logo

Samsung RS261M - Weak Cooling Performance Issues

Samsung RS261M
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 38/47 -
Check-1
Reason Step
Check-2
Tip
Code
Block
# 1
# 2
# 3
WEAK
COOLING
Inspect F WEAK
COOLING
Inspect R WEAK
COOLING
Self diagnosis test
Display “Lighting”+
“Energy Saver
9-1
Ice
Maker
Sensor
Fan
Damper
Wire
Harness
Main
PBA
Measure cooling
power inspection
Inspect Comp / Fan
motor
9-2
Comp
Relay
Cycle
Shield
System
C-fan
DEFROST BUILD
9-3
DEF-Sen
sor
Heater
Main
PBA
TOO COLD
R TOO COOLING
Inspect ASSY COVER
DAMPER
Inspect ASSY INS-
DAMPER
10-1
Cover
Damper
INS-
Damper
Chassis
Basic Model
Type
SBS
RS261M*
Plastic Ice Maker
※ Operate self-diagnosis test
COOLING
#1. Symptom : WEAK COOLING & TOO COLD Repair

Related product manuals