- 39/47 -
※ Fan motor displays failure only for power On
condition.
Press Display “Lighting”+ “Energy Saver” Key for
8sec at the same time.
- Press until “Dingdong” sound appear after all
LEDs is blinking
- No problem on self-diagnosis test Check
TIP 9-2
Tip 9-1. Inspect self-diagnosis test (※ Must select “Power Freeze” first)
Inspect F ice maker + Wire
Harness
① F ice maker connector
② Main PBA CN90
Ice Maker function
failure
Disassemble Cover Multi Front
① Inspect Sensor Wire
② Main PBA CN40 No.5(YEL)
CN50 No.5(GRY)
Disassemble Cover Evap
① Inspect Sensor Wire
② Main PBA CN40 No.6(BLU)
CN50 No.5(GRY)
Disassemble Cover Multi
① Inspect Fan Wire
② Main PBA CN75
No.4(YEL)+No.5(BLK)+No.1
0(GRY)
Check disassembled Evap
Cover defrost heater
① Inspect defrost heater
housing
② CN70 No.5(BRN)+CN72
No.1(ORG)
Disassemble R Cover Damper
① Main PBA CN40 No.9(BLK)
CN50 No.5(GRY)
R
vibration
Damper
Heater
Disassemble R Cover Damper
① Inspect Main PBA CN76
No.4~9
Inspect disassembled
machinery room COVER C-Fan
Check disassembled R door
HINGE-UPP
① Main PBA CN40
- No.1(YEL)+No.2(YEL)