Tip 9-1-2. Inspect self-diagnosis test
F Sensor / cabinet Fan / Defrost Sensor / Defrost Error
Block
Disassemble F Ice Maker Screw top
Inspect disassembled Cover Multi Front
Inspect disassembled Evap Cover
Circuit diagram
When F cabinet Sensor is
failure
: Inspect disassembled Cover
Multi Front blue 2-Wire
connector
-Main PBA : CN40 No.5(YEL)
+ CN50 No.5(GRY)
When F Fan is failure
: Inspect disassembled Cover
Multi Front 3-Wire connector
-Main PBA : CN75 4(YEL) /
5(BLK) / 10(GRY)
When Defrost Sensor is
failure
: Inspect disassembled Evap
Cover blue 2-Wire
-Main PBA : CN40 No.6(BLU)
+ CN50 No.5(GRY)
Defrost Error
: Inspect brown 2-Wire
connector
-Main PBA : CN70 No.5(BRN)
+ CN71 No.1(ORN)
Main PBA
CN 50
F-Sensor
Fan Motor
D-Sensor
Heater
Defrost
Sensor
CN 40
CN 70,71
CN 75