EasyManua.ls Logo

Samsung RS261M - Page 46

Samsung RS261M
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 46/47 -
Step 1
Press Display “Lighting”+ “Energy Saver” Key for
8sec at the same time until “Dingdong” sound
appears
※ when the Error occurs Measure to move
TIP 5-1.
- When there is no ERROR, DEFROST ERROR
Check Step2
Step 2
Disassemble EVAP COVER EVAP-FRE FRONT
& COVER Multi.
Melt the right connector with steamer and
disassemble the cover.
Step 3
Measure BROWN WIRE resistance.
- Normal part : 35~60
- Failure part : Open or 0 Ω
Replace HEATER & BIMETAL OPEN
because it is failure.
Step 4
When DEFROST SENSOR part is freezing,
replace it because it is the failure of Sensor.
Step 5
There is no freezing on bottom and DEF-
SENSOR and top middle part has freezing
-Move DEF-SENSOR location to center of
pipe.
Tip 9-3. Inspect EVAP DEFROST BUILD
Defrost
Error
HEATER
& BIMETAL
BIMETAL
MOVE
※ Do not off the power and operate self-diagnosis test toTIP 5-1”
first.
Must check the forced defrost operation after defrost repairing.
Next Page