Step 6
When EVAP BOTTOM is freezing only
- improve DRAIN freezing.
Check Drain hole blocking with remove
freezing with STEAMER.
(Remove DRAIN freezing and foreign
substance)
Bending the HATER to bottom with hand.
- DRAIN HOLE Should be closed.
HEATER can not contact to PLATE.
Step 7 (Total inspection after defrost repairing)
Check Heater operation with forced defrost
operation after complete repairing.
Press “Lighting”+ “Fridge” at the same time
to make ALL LED OFF and operate forced
defrost with pressing “Fridge” key 2times.
Check heater(Brown-wire) AC voltage
supplying when the “beep” sound appears.
Off with same way if there is no problem.
Forced
operation
(LED Full On)
Forced defrost
OFF
Step 8
When there is no AC power supplying,
inspect MAIN PBA and CONNECTOR OPEN .
Replace Main PBA if there is no problem.
Inspect MAIN PBA CN70 No.5
(BRN)+CN71 No.1(ORG)
- LINER CONNECTOR BROWN
2WIRE
LED ALL OFF