5
[CFC-FREE]
ITEM
Model
Power source
STANDARD(MECHANICAL TYPE)
Evaporator
Condenser
Dryer
Capillary tube
Resistor Heater
Heater-defrost
Lamp
Door-Switch
Earth screw
Model
Starting type
Oil charge
Compressor
Refrigerator
Thermal fuse
Model
Thermostat
Bimetal
(OFF/ON)
Defrost-thermo
PTC-relay
Capacitor
Overload
protector
Type
Defrosting
Interval
Model
Resistance
Close temp.
Open temp.
Running
Defrost-timer
Refrigeration Cycle
Electrical
R.S.C.R
110~115V/60Hz
UK162C-L1U/T3
127V/60Hz
UK162P-L1U/T3
220V/50~60Hz
SK182H-L2U/E02
FREOL α–15c / 200cc
Fin type
Natural convection type
Molecular sieve (XH-9, 13g)
ID 0.75 x L3400 (mm)
PFN-174S-05F (ON:5.5
˚C±
1.5
˚C
OFF:+3.0
˚C±
1.5
˚C
)
250V/0.5A, 125V/1.5A
BSBN(Brass screw)
Rating Voltage/Ampere
Open temperature
Rating Voltage/Ampere
Open temperature
TMDE714F1
AC 250V / 5A
ON:-5±3˚C/OFF:12±3˚C
AC 250V / 10A
77±10˚C
TD-20CSA
69±9˚C
120±5˚C
250VAC/12
µF
69±9˚C
125±5˚C
350VAC/5.0
µF
J531Q33E100M 200-2
10-2PIN
6hr 40min(60Hz)/8hr(50Hz)
12Min
J531Q34E220M350-2
22-2PIN
4TM419
NHBYY-53
4TM308
PHBYY-53
MORS 1.2W
290W/45 290W/167
220V~240V/15W
RT40/44MA/MB