LG_MULTI_F_3828A20097W_1[1]
4-1-1-1-2. Models with ROTARY S/W (Fridge
1. If repeating 3 times switch of
'Coldest' Choices as Rotary Switch
and "Dead Zone" over a second choice, a Test key will be
recognized as a one circuit. However, the
"Dead zone" exceed 5 seconds.
3 time Count is initialized.
2. Start typing TEST KEY and Forced Operation → Forced F-Defrost
→ Cancellation (Normal Operation) → Forced Operation. Test
feature is changed as the sequence to forced operation.
3. In a Normal mode, Test Key recogn
4. If forced operation is selected, even in action, COMP will work immediately without 7-minute delay.
5. If forced operation is selected, defrost immediately is interrupt.
6. If forced operation is selected,
COMP. and F-FAN continuously operate for 24 hours.
7. The forced operation continues to operate until completed or different MODE is switched or released (force
8. Once forced operation is complete (24 hours). F defrost is proceeded regradess of the previous state.
9. After the defrost operation depending on the completion of the forced operation by judging and operating
CASE which performs defrost function, it is proceeded a the normal defrost conditions.
10. Forced Operation → Forced F-Defrost → Cancellation (Normal Operation)
feature is changed as the sequence to forced operation.
Dead zone : If do not set a specific Notch, set between Notch, It is recognized as not the middle value
but abnormal range. This is called
※REFERENCE : TEST OPERATION BLOCK DIAGRAM (TEST MODE)