LG_MULTI_F_3828A20097W_1[1]
4-2-1. When Self-Diagnosis Error occurs
- The Display Panel shows the Sensor Error and, when the unit is plugged in and there are sensor errors,
the unit does not operate and Display bar related to the defective sensors keep blinking.
- When sensor defects occur during the operation, the unit keeps working. But, it shifts to the Emergency
Operation and it may not work properly. So, please check the
unit according to the Self Diagnosis function.
CN30 is inserted properly?
MAIN PCB Connector CN30-"5"(ORG)
PCB and Temp Sensor are normal.
Check the connector contact.
Connector contact defect /
Check the wire connection
Check Soldering Defect & Short
NO(Value < 0.6V or Value > 4.6V)
"5"(ORG) and CN30-"7"(GRY)
Voltage : Between 4.6V ~ 0.6V
** Sensor Resistance Reading Location **
R : Between CN30 #5 and #7
** 0Ω : Short / ∞Ω : Open
23 is the same as the value
1) When the R-Sensor is defective