[ Freezer Defrost Heater ]
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Freezer Defrost When the defrosting
does not complete even after it does
defrosting for more than 120 minutes.
Remove the MAIN PCB CN70 and CN77
connectors from the MAIN PCB and
read the continuity between BROWN ↔
(It differs according to the
if the Wire/Thermal Fuse or the
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
(higher than +65℃ or lower than -50℃)
The voltage between MAIN PCB CN31-
"1(WHT) ↔ 2(WHT)" should be within
The voltage between MAIN PCB CN30-
"5(ORG) ↔ 7(Gray)" should be
Same as the EXT - SENSOR
The voltage between MAIN PCB CN30-
"4(RED) ↔ 7(Gray)" should be within
occurs if the contact of the Feed Back
Signal Wire is defective, the Motor Wire
is slipped out or the Motor is
The voltage between MAIN PCB CN72-
"9(S/BLU) ↔ 10(GRY)" should be
The error code is displayed when the
compressor has failed to start.
Check the soldering status of the
circuited). Check if the DC 16V output is
less than 13.5V. Check the Comp
The error code is displayed when
the compressor IPM fault error has
The error code is displayed when the
compressor location detection failed.
Check the compressor wire
of the inverter PCB. (Check if any
The error code is displayed when the
compressor motor is constrained.
Check if the compressor and the Cycle is
normal. Check the input voltage.
Check the soldering of the inverter PCB.
(Check if any parts have short-circuited.)
The error code is displayed when the AC
Input Voltage is too low.
Check the input voltage. (This error occurs
when the input voltage is AC 106 V or
Check the input voltage. (This error occurs