LG_MULTI_F_3828A20097W_1[1]
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
The voltage between MAIN PCB CN30-
"4(RED) ↔ 7(Gray)" should be within
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
The voltage between MAIN PCB CN31-
"1(WHT) ↔ 2(WHT)" should be within
[ Freezer Defrost Heater ]
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
Freezer Defrost When the defrosting
does not complete even after it does
defrosting for more than 120 minutes.
Remove the MAIN PCB CN70 and CN77
connectors from the MAIN PCB and
read the continuity between BROWN ↔
ORG wires. (It differs according to the
if the Wire/Thermal Fuse or the
Connector Slipped-Out or Open-
Contact, Wire Cut or Short-Circuited,
The voltage between MAIN PCB CN30-
"5(ORG) ↔ 7(Gray)" should be
PBA-Rotary Switch Slipped-Out or
Circuited,Switch Part Defect
The voltage between MAIN PCB CN30-
"3(BRN)↔ 7(Gray)" should be within
The error code is displayed when the
compressor has failed to start.
Check the soldering status of the
inverter PCB. (Check if any parts have
output is less than 13.5V. Check the
The error code is displayed when
the compressor IPM fault error has
The error code is displayed when the
compressor location detection failed.
Check the compressor wire connections.
Check the soldering status of the inverter
PCB. (Check if any parts have short-
circuite d). Check the Comp and Cycle.
The error code is displayed when the
Check if the compressor and the Cycle
is normal. Check the input voltage.
Check the soldering of the inverter PCB.
The error code is displayed when the
Check the input voltage. (This error
occurs when the input voltage is AC
Check the input voltage. (This error