22 _ Troubleshooting
Code Type Code Mode Causes Corrective Actions Description of Photo
Water Supply
Code
►ExtraHigh
LED Flash
This may occur when the
water supply valve is
defective.
If the water supply valve is broken, replace
the valve.
Check if the water supply is blocked due
to an alien substance in the valve or check
if the water is supplied to the machine. If
a problem is found, take the appropriate
countermeasure.
Check if the water supply is blocked due to
the water being frozen.
If the PBA Relay malfunctions, replace the
PBA.
1. Measure the resistance of the
water supply valve.
- Resistance:0.9KΩto1.1KΩ
between the terminals of the
Water Supply Valve.
2. Check whether there is foreign
material in the Water supply
valvelter.
►Hot&Low
LED Flash
This may occur when the
main PCB is defective.
This may occur due to
frozen water.
Drain Code
►LowLED
Flash
This may occur when the
drain pump is defective.
Check if there is any alien substance inside
the draining pump motor.
Check the natural drain in the same manner.
Check if there are any incorrect connections
or broken wires.
If the machine malfunctions intermittently
when the wash tub water temperature is
high, replace the pump.
If the motor stops due to the water being
frozen in winter, remove the frozen water
referring to the relevant repair procedures.
Check the drain pump resistance.
(Resistance:13.5~16.5Ω)
This may occur due to
frozen water.
Check if there is any alien
substance inside the
draining pump.
This may occur when the
main PCB is defective.
Communication
Code
►WarmLED
Flash
The signals between the sub
and main PBAs are not
sensed.
Check the wire connections and terminal
contacts between the sub and main PBAs.
Check for disconnected wires.
Check whether the sub PBA is short-circuited
because of moisture.
If the main PBA’s communication circuit is
faulty, replace it.
-
Incorrect wire connections
between the sub and main
PBAs.

Related product manuals