24 _ Troubleshooting
Symptom Check Code Countermeasure Troubleshooting Procedure Measurement Picture
Door Code
HotLED
Flash
This may occur when the
door switch is defective.
This may occur when the
main PCB is defective.
CheckiftheseLEDashduringtheboiling
course.
AstheseLEDashbecausethedooris
opened, close the door.
Since 120V power is connected, check if
the power cord is disconnected or check the
insulation status and repair it if necessary.
If the main PBA door detection circuit is
defective, replace it.
1. Check the resistance for Reed
SW (Checking Part :White-Green
Wire)
- Resistance:Approx0.2Ω
between the terminals of
Reed SW.
Hot&High
LED Flash
2. Check the resistance for Motor
(Checking Part : Black-Brown
Wire)
- Resistance:33Ωto46Ωbetween
the terminals of Motor.
Hot&Extra
High LED
Flash
The door lock switch unit is
not inserted.
The door lock switch unit is
damaged.
The wire is disconnected.
The door lock switch unit is
defective.
This may occur due to a
defect of the main PCB.
Check whether the door lock switch unit is
inserted.
Check whether the door lock switch unit is
damaged.
Check the disconnection of the wire.
If the door lock switch unit is defective,
replace it.
If the main PCB is defective, replace it.
3. Check the resistance for Lock/
Unlock Contact
(Checking Part : Lock White-Red
Wire Unlock White-Blue Wire)
- Resistance: Resistance:
Approx0.2Ωbetweenthe
terminals of Contact.
Check the Door Lock/Unlock
state.
HotHigh
LED Flash
Temperature
Sensor Code
Hot&Mid
LED Flash
Heater fault
Thermistor fault
Poor physical connection
Check whether Thermistor is inserted.
Check whether Thermistor is damaged.
Check the disconnection of the wire.
If Thermistor is defective, replace it.
If the main PCB is defective, replace it.
Check Resistance for Thermistor
(Checking part : Pin #3 and #9 of
CN10)
•Resistance:Approx47(at
25ºC) between the terminals of