40 _ Troubleshooting
Error Type
Drum
Fully
automatic
Causes Remarks
Error
mode
Old
error
mode
For USA
Temperature
Sensor Error
tE1
tE1
6E
tE -
- Thewashingheaterinthetubhasanerror.
(Contacterror,temperaturesensorfault)
- Theconnectorisconnectedincorrectlyoris
disconnected.
- Ifthewaterlevelsensoroperateswithoutwater
becausethewaterisfrozenorforanyother
reasonandthetemperaturesensorengagedat
thebottomtopreventoverheatingforthewashing
heaterdetectsatemperatureof100to150˚C,
thewashingmachineturnstheinputpoweroff.
Heatersensor
fault
:Whenthe
connectoris
connected
incorrectlyor
hasawire
disconnected
orcontacterror
tE2 tE2 - -
- Thetemperaturesensorfortheductassyfan
housingisfaulty.
(Asensorfaultsuchasaninternalshort-circuitor
wiredisconnection)
- Theconnectorisoutofplaceorhasacontact
error.
Duct
condensing
temperature
sensorfault(for
modelsbefore
thesilvernano
functionwas
applied)
tE3 tE3 - -
- Thisoccurswhentheductcondensing
temperaturesensorisopen.
- Thisoccurswhentheductcondensing
temperaturesensorhasawiredisconnectedoris
short-circuited.
- Theconnectorisoutofplaceorhasacontact
error.
Dryheater
temperature
sensorfault(for
modelsbefore
thesilvernano
functionwas
applied)
Unbalance
Error
UE
UE
E4
dc UE
- Aslaundrycausesthiserror,checkthelaundry.
- Findthereasonfortheunbalanceandsolveitas
directedintheusermanual.
Foaming
Detected
Sud - SUdS -
- Thisoccurswhentoomuchfoamingisdetected.
Itisalsodisplayedwhilefoamingisremoved.
Whentheremovalisnished,thenormalcycle
proceeds.“Sud”or“SUdS”isdisplayedwhentoo
muchfoamingisdetectedand“End”isdisplayed
whentheremovalofthefoamingisnished.
(Thisisoneofthenormaloperations.Itisanerror
forpreventingnon-sensingfaults.)
Mems PBA
Error Detected
- - E8 -
- ErrordetectedintheMemsPBAordataerror
detected.Checkthewireconnections.
Replaceifnecessary.
1. Checkthewireconnections.
2. ReplacetheMemsPBA.
3. MainPBAwireconnectionerrororPBA’ssilver
nanopartmalfunction.Replaceifnecessary.